- Operating Temperature:
-
- Features:
-
- Termination Style:
-
- Contact Form:
-
- Coil Current:
-
- Coil Voltage:
-
- Switching Voltage:
-
- Turn On Voltage (Max):
-
- Turn Off Voltage (Min):
-
- Selected conditions:
Discover 60 products
Image | Part Number | Manufacturer | Quantity | Delivery period | Unit Price | Buy | Description | Series | Operating Temperature | Features | Termination Style | Contact Form | Coil Current | Coil Voltage | Contact Rating (Current) | Switching Voltage | Turn On Voltage (Max) | Turn Off Voltage (Min) | Operate Time | Release Time | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Image | Part Number | Manufacturer | Quantity | Delivery period | Unit Price | Buy | Description | Series | Operating Temperature | Features | Termination Style | Contact Form | Coil Current | Coil Voltage | Contact Rating (Current) | Switching Voltage | Turn On Voltage (Max) | Turn Off Voltage (Min) | Operate Time | Release Time | ||
Omron Automation and Safety |
450
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPDT 5A 24V
|
G2RS | -40°C ~ 70°C | Diode,LED Indicator | Plug In | DPDT (2 Form C) | 21.6mA | 24VDC | 5A | 380VAC,125VDC - Max | 16.8 VDC | 3.6 VDC | 15ms | 20ms | ||||
Omron Automation and Safety |
23
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 24V
|
MKS-X | -40°C ~ 60°C | - | Plug In | SPST-NO (1 Form A) | 63.2mA | 24VDC | 10A | 220VDC - Max | 19.2 VDC | 3.6 VDC | 30ms | 20ms | ||||
Omron Automation and Safety |
23
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 240V
|
MKS-X | -40°C ~ 60°C | - | Plug In | SPST-NO (1 Form A) | 9.6mA | 240VAC | 10A | 220VDC - Max | 192 VAC | 72 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
30
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 120V
|
MKS-X | -25°C ~ 60°C | Mechanical Indicator | Plug In | SPST-NO (1 Form A) | 19.3mA | 120VAC | 10A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
14
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 24V
|
MKS-X | -40°C ~ 60°C | - | Plug In | DPST-NO/NC (1 Form A and B) | 63.2mA | 24VDC | 5A | 220VDC - Max | 19.2 VDC | 3.6 VDC | 30ms | 20ms | ||||
Omron Automation and Safety |
6
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 12V
|
MKS-X | -25°C ~ 60°C | Mechanical Indicator | Plug In | SPST-NO (1 Form A) | 126mA | 12VDC | 10A | 220VDC - Max | 9.6 VDC | 1.8 VDC | 30ms | 20ms | ||||
Omron Automation and Safety |
26
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 120V
|
MKS-X | -25°C ~ 60°C | Mechanical Indicator | Plug In | DPST-NO/NC (1 Form A and B) | 19.3mA | 120VAC | 5A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
16
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 24V
|
MKS-X | -25°C ~ 60°C | Mechanical Indicator | Plug In | DPST-NO/NC (1 Form A and B) | 63.2mA | 24VDC | 5A | 220VDC - Max | 19.2 VDC | 3.6 VDC | 30ms | 20ms | ||||
Omron Automation and Safety |
14
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 120V
|
MKS-X | -25°C ~ 60°C | LED Indicator,Test Button | Plug In | DPST-NO/NC (1 Form A and B) | 19.3mA | 120VAC | 5A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
13
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 24V
|
MKS-X | -25°C ~ 60°C | LED Indicator,Test Button | Plug In | DPST-NO/NC (1 Form A and B) | 63.2mA | 24VDC | 5A | 220VDC - Max | 19.2 VDC | 3.6 VDC | 30ms | 20ms | ||||
Omron Automation and Safety |
28
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 24V
|
MKS-X | -40°C ~ 60°C | - | Plug In | SPST-NO (1 Form A) | 96.3mA | 24VAC | 10A | 220VDC - Max | 19.2 VAC | 7.2 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
30
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 120V
|
MKS-X | -40°C ~ 60°C | Test Button | Plug In | SPST-NO (1 Form A) | 19.3mA | 120VAC | 10A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
10
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 24V
|
MKS-X | -25°C ~ 60°C | Mechanical Indicator | Plug In | SPST-NO (1 Form A) | 96.3mA | 24VAC | 10A | 220VDC - Max | 19.2 VAC | 7.2 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
40
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 120V
|
MKS-X | -40°C ~ 60°C | Test Button | Plug In | DPST-NO/NC (1 Form A and B) | 19.3mA | 120VAC | 5A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
14
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 24V
|
MKS-X | -40°C ~ 60°C | Test Button | Plug In | DPST-NO/NC (1 Form A and B) | 63.2mA | 24VDC | 5A | 220VDC - Max | 19.2 VDC | 3.6 VDC | 30ms | 20ms | ||||
Omron Automation and Safety |
34
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 120V
|
MKS-X | -25°C ~ 60°C | LED Indicator,Test Button | Plug In | SPST-NO (1 Form A) | 19.3mA | 120VAC | 10A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
5
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 12V
|
MKS-X | -40°C ~ 60°C | - | Plug In | SPST-NO (1 Form A) | 126mA | 12VDC | 10A | 220VDC - Max | 9.6 VDC | 1.8 VDC | 30ms | 20ms | ||||
Omron Automation and Safety |
Inquiry
|
- |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 120V
|
MKS-X | -40°C ~ 60°C | - | Plug In | SPST-NO (1 Form A) | 19.3mA | 120VAC | 10A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
3
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE DPST 5A 120V
|
MKS-X | -40°C ~ 60°C | - | Plug In | DPST-NO/NC (1 Form A and B) | 19.3mA | 120VAC | 5A | 220VDC - Max | 96 VAC | 36 VAC | 20ms | 20ms | ||||
Omron Automation and Safety |
1
|
3 days |
-
|
MOQ: 1 MPQ: 1
|
RELAY GEN PURPOSE SPST 10A 24V
|
MKS-X | -25°C ~ 60°C | LED Indicator,Test Button | Plug In | SPST-NO (1 Form A) | 63.2mA | 24VDC | 10A | 220VDC - Max | 19.2 VDC | 3.6 VDC | 30ms | 20ms |